Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange.

Engtips. Things To Know About Engtips.

When you think about shared micromobility, Veo isn’t exactly the first company that comes to mind. It’s not as widespread as competitors like Voi, Tier and Lime, and it hasn’t rais...UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Water treatment & distribution. (21029 members) forum164 - Professional forum and technical support for engineers for Water treatment & distribution. Includes problem solving collaboration tools. Forum.

Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools.

Jan 26, 2024 · The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites themselves.

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... To Remove or insert a Spacer or Blind you first depressurize the System, Then make it Safe. Then you remove all the Bolts on One (1) side of the Flange set. Then you "Jack" the Flanges apart using the built-In Jack Screws (in the Flanges) or with Flange Spreaders (Look it up). Now with the Flanges spread …Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering … Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools. Happy Friday. Looking at replacing the entire bottom of a 60' diameter tank. Given the foundation configuration and some other challenges, the recommended solution is to install a second bottom over the existing bottom as specified in API 653 9.10.2. Looking for a couple bench marks from members. - Confirmation there isn't an API-653 standard ...

Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …

Thank you for helping keep Eng-Tips Forums free from inappropriate posts. The Eng-Tips staff will check this out and take appropriate action. Close. Reply To This Thread Posting in the Eng-Tips forums is a member-only feature. Click Here to join Eng-Tips and talk with other members! Already a Member? Login.

At the moment we have 870525 registered users, who have published 99622 materials and shared 554052 comments. Englishtips.org was launched in 2005. In the last 24 hours …Jan 26, 2024 · The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites themselves. Chemical plant design & operations. (33961 members) forum124 - Professional forum and technical support for engineers for Chemical plant design & operations. Includes problem solving collaboration tools. One World Pharma News: This is the News-site for the company One World Pharma on Markets Insider Indices Commodities Currencies StocksEarthwork/grading engineering. (18515 members) forum158 - Professional forum and technical support for engineers for Earthwork/grading engineering. Includes problem solving collaboration tools. Forum.From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—...*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home; Forums; Structural Engineers; Activities; Welding, Bonding & Fastener …

Foundation engineering. (26096 members) forum256 - Professional forum and technical support for engineers for Foundation engineering. Includes problem solving collaboration tools. Forum. Search.The nosing provides clearance space for your heel to drop on the tread. If there were no nosing, your heel might hit the riser and you will stumble forward (and probably fall if you are not holding n the handrail). msquared48 (Structural) 20 Apr 09 19:27. To encourage tripping as you go up the stairs.Ayurveda. Unani. Homeopathy. Cowpathy. You’ve heard of ayurveda, the traditional Indian medical science. So have you about Unani, the Perso-Arabic healing science. Then there is ho...Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …Phone Number (510) 595-2220. Eng-Tips is a forum for Engineering professionals that is designed to facilitate discussion and research for engineering professionals. Eng-Tips …

The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is …Mar 22, 2023 · From reading XR250s posts I think this is how he approaches it as well. 3. YoungGunner (Structural) 23 Mar 23 15:22. Having worked in residential for 7 years now, I have a few thoughts on the matter: First off, the IRC already shows questionable engineering compared to our "big boy" design standards/codes.

InvestorPlace - Stock Market News, Stock Advice & Trading Tips As energy prices continue to climb, it makes sense to look for oil stocks to bu... InvestorPlace - Stock Market N...Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an 8" masonry bearing wall...not 4" load bearing block with 4" veneer. The building depts around are extremely quick to call out 'brick veneer' can't be used for connecting or ...Actuators are Rotork, valves are a well-known Western manufacturer. One of the actuators is sized at 100% of predicted valve operating torque. To me this instinctively feels incorrect - I made a few calls to friends elsewhere who both suggested actuators are normally capable of 150% - 200% of valve rated torque, …From raising minimum wages to "staple green cards." The allocation of H-1B visas is very inefficient, with the lottery system being used in the years with the greatest visa demand—...Its total height is 140 mm, where height of steel deck is 60 mm and height of concrete above slabs is 80 mm, so I've put that both membrane and bending thicknesses are 140mm = 0,14m. As a material I've chosen concrete C30/37 defined in Materials (I'll attach my model in SAP2000 at the end of the post). This concrete's Weight per Unit Volume is ... Water treatment & distribution. (21029 members) forum164 - Professional forum and technical support for engineers for Water treatment & distribution. Includes problem solving collaboration tools. Forum.

Makes sense to do so. EIT. hawkaz (Structural) 1 Sep 11 19:08. 40 psf is a good number. 4000# car over a 9'X18' space = 25 psf. I would put the full snow load on the roof in addition to the 40 psf load (both can be there at the same time). msquared48 (Structural) 1 Sep 11 19:45. 6000# (Suburban)over 9X18 is 37.

See thread507-434895: Tension Field Action - End panels in Old Codes. BA. rb1957 (Aerospace) 7 Sep 20 22:16. the author makes the point that the end bays usually don't have the stiffener at the extreme end of the beam, and so the web cannot develop the shear buckles. In the example R13 posted these end panels aren't doing anything to react the ...

Beijing approves the first vaccine of its kind as it looks to jumpstart its flailing economy China has approved a Covid-19 vaccine utilizing MRNA technology for the first time ever...22 hours ago · The Eng-Tips staff will check this out and take appropriate action. Close. Reply To This Thread Posting in the Eng-Tips forums is a member-only feature. Makes sense to do so. EIT. hawkaz (Structural) 1 Sep 11 19:08. 40 psf is a good number. 4000# car over a 9'X18' space = 25 psf. I would put the full snow load on the roof in addition to the 40 psf load (both can be there at the same time). msquared48 (Structural) 1 Sep 11 19:45. 6000# (Suburban)over 9X18 is 37.Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …Storage tank engineering. (6881 members) forum1452 - Professional forum and technical support for engineers for Storage tank engineering. Includes problem solving collaboration tools. Search.Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. Hot dip galvanized anchor bolts should be used if corrosion is a concern. Do not have regular black anchor rods galvanized, since the clearances would not be correct. As stated above, you can also coat the exposed portions with grease, paint, gooey-anti-corrosion-stuff, or whatever after fastening, but not before.Joints spacing: • Rule of thumb is 24 to 36 times the thickness (gives the spacing in mm/inches). • Keep the thickness variation to -5mm (-1/4") / +10mm (3/8"), and the subgrade as flat as possible with no abrupt change greater than 15mm (1/2") in about 1.2m (4'). This keeps the "sudden" restraint potential down.As a foundry engineer in a Aluminnum foundry we fight this with customers all the time. #1- Aluminum has roughly 1/2 the Brinell of iron ( hardness) thiss means if you used 6 - 3/8X16 x 1 bolts on a iron part you better look at. using 10 1/2 x 13 x 1.5 in aluminum. We also push Heli coils. Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.

We calculate the rms value of fault current (If) at the onset of it (t=0sec), using subtransient values of reactances for the sources and taking no account of the dc component. Then, the make current is : 2.55*If. and break current is : 1.255*If. with dc component included in both cases. dpc (Electrical) 23 Jan 02 …Start with the loaded front wheel loads. The 8000 pounds is presumably the lift capacity and not the total loaded weight. Looking at the contact patch on the loaded front tires will give you a sense of the local punching and beam shear demand-to-capacity ratios. Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search. Instagram:https://instagram. what time is it in ohio usabluepeak outage mapwaiting to exhale full movie 123moviesnearest bank of america drive thru As a foundry engineer in a Aluminnum foundry we fight this with customers all the time. #1- Aluminum has roughly 1/2 the Brinell of iron ( hardness) thiss means if you used 6 - 3/8X16 x 1 bolts on a iron part you better look at. using 10 1/2 x 13 x 1.5 in aluminum. We also push Heli coils. weather nyc 10031hair salons that perm hair near me UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.In linear analysis, starting from displacements, the nodal forces can be calculated in two equivalent ways: a) R_e = K_e * U_e. b) At each integration point, calculate strains using B (m) * U_e, calculate stresses using C*e, then integrate stresses using Eq. 4.29. R_e: element nodal force. how to beat night 2 sister location funtime freddy Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality.